Remove Debris Cup from the Nosepiece.
-
Remove Nosepiece from the Reset Sleeve. Use the included wrenches for assistance as necessary.
-
Slide the Spacer off the threads of the Nosepiece as necessary.
-
Remove the base from the tool.
-
Slide the Firing Spring off the tool. Note the Buffer is attached to the end of the Firing Spring (NTS101-9). Check condition of Firing Spring and Buffer.
-
Slide off the Outer Cover Sleeve.
-
Depress the Reset Spring (NTS5X-11) to collapse the Reset Sleeve. This will loosen the Main Assembly Pin and allow it to be removed from the tool.
-
Slide the Main Firing Assembly from the main body of the tool.
-
Depress the Trigger Ball to compress the Trigger Ball Spring and slide the Firing Pin Assembly from the Firing Pin Guide.
-
Keep pressure over the Trigger Ball to hold it in place while removing the assembly. Releasing the Trigger Ball may cause it to spring up.
-
Once the Firing Pin Assembly has been removed from the Guide, slowly release the Trigger Ball and remove it from the Firing Pin Holder.
-
To remove the Firing Pin, use the provided firing pin punch and knock out the 1/8” Roll Pin.
Download the Tool Disassembly Instructions here.
1.
NITROSET® Tool Cleaning Procedure
- It is recommended that the NITROSET® tool be cleaned every day after use. Proper maintenance and cleaning of the tool enables the tool to operate at peak performance.
- First, be sure all fastener assemblies and debris are ejected from the tool by resetting it pointed away from yourself or any bystanders.
- Remove the muzzle by unscrewing it from the tool shank. Then, remove the end cap and disassemble the entire tool following the tool disassembly instructions.
- Empty the debris cup.
- To clean, use a diluted industrial degreaser or cleaner similar to Strike-Hold (provided in tool kit) or other similar non-oil base degreaser to spray or wipe the tool surface and threads. Allow contact time of 3 to 5 minutes before scrubbing. Wipe off excess cleaning agent and allow tool to fully dry before reassembly.
- Re-assemble the tool. For long term storage, thread the nosepiece halfway to prevent debris build up from forming rust on the fine thread.
2.
Interim Cleaning Procedure
- Empty the debris cup after every 500 fastenings, or as needed to optimize performance.
- A liquid shot of degreaser lubricant at approximately every 500 to 1000 fastenings is recommended to maintain a smooth operation.
- This will help tool performance and actuating consistency, making your end-of-day cleaning easier.
-
Assemble Firing Pin (NTS101-4) into Firing Pin Holder using the 1/8″ Roll Pin (NTS101-8).
-
Insert Trigger Ball Spring (NTS101-5) into Trigger Ball (NTS101-7) and place into the Holder.
-
Slide complete Firing Assembly into the Guide while depressing the Trigger Ball until it clicks into the Guide.
-
Insert Guide and Holder through the Reset Sleeve. Attach Reset Spring (NTS5X-11) to Reset Sleeve.
-
Insert Reset Sleeve into the Trigger Body. Make sure the trigger key on the body aligns properly with the Trigger Ball.
-
Insert Main Assembly Pin (NTS5X-12). Ensure coils of the Reset Sleeve are all above the pin.
-
Slide Outer Cover Sleeve over the Trigger Body.
-
Insert the Firing Spring (NTS101-9) with the Buffer attached over the Holder.
-
Attach the End Cap of the tool.
-
Secure the Debris Cup to the Nosepiece.
-
Slide appropriate Spacer onto the Nosepiece.
-
Secure the complete Nosepiece Assembly onto the Reset Sleeve.